国产精品久久久在线观看_亚洲免费观看视频网站_国产盗摄视频一区二区三区_久久久国产一级 - 日本在线观看一区

歡迎來(lái)到寰標(biāo)網(wǎng)! 客服QQ:772084082 加入會(huì)員

IEC 60840:2020 PRV即將實(shí)施

Power cables with extruded insulation and their accessories for rated voltages above 30 kV (Um = 36 kV) up to 150 kV (Um = 170 kV) - Test methods and requirements - Pre release version

出版:International Electrotechnical Committee

獲取原文 如何獲取原文?問(wèn)客服 獲取原文,即可享受本標(biāo)準(zhǔn)狀態(tài)變更提醒服務(wù)!

專家解讀視頻

基本信息
標(biāo)準(zhǔn)編號(hào): IEC 60840:2020 PRV
出版單位:International Electrotechnical Committee
標(biāo)準(zhǔn)頁(yè)數(shù):83
標(biāo)準(zhǔn)簡(jiǎn)介

This Final Draft International Standard is an up to 6 weeks' pre-release of the official publication. It is available for sale during its voting period: 2020-02-28 to 2020-04-10. By purchasing this FDIS now, you will automatically receive, in addition, the final publication. IEC 60840:2020 specifies test methods and requirements for power cable systems, cables alone and accessories alone, for fixed installations and for rated voltages above 30 kV (Um = 36 kV) up to and including 150 kV (Um = 170 kV). The requirements apply to single-core cables and to individually screened three-core cables and to their accessories for usual conditions of installation and operation, but not to special cables, such as submarine cables and their accessories, for which modifications to the standard tests or the setup of special test conditions can be necessary. This document does not cover transition joints between cables with extruded insulation and paper insulated cables. This fifth edition cancels and replaces the fourth edition, published in 2011. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - Gas immersed cable terminations for use at rated voltages above 52 kV are required to be designed, type and routine tested in accordance with IEC 62271-209 in addition to the routine and type tests specified in this document. - Requirements are introduced for composite outdoor termination insulators. - The test cylinder diameters specified for the bending test (type and prequalification tests) have been modified in line with IEC TR 61901:2016. - A low smoke halogen free oversheath material, designated ST12 is introduced. - Additional tests under fire conditions are introduced: vertical flame spread, smoke density, acidity and conductivity, which shall be applied according to the fire performance declared for the cable. - A test for water penetration in the conductor is added. - In addition to tests on the outer protection of joints, type tests on the screen sectionalizing insulation of all accessories have been introduced.