High-voltage switchgear and controlgear Part 110: Inductive load switching

出版:International Electrotechnical Committee

獲取原文 如何獲取原文?問客服 獲取原文,即可享受本標(biāo)準(zhǔn)狀態(tài)變更提醒服務(wù)!

專家解讀視頻

基本信息
標(biāo)準(zhǔn)編號: IEC 62271-110 Ed. 1.0
發(fā)布時間:2005/6/24 0:00:00
標(biāo)準(zhǔn)類別:Standard
出版單位:International Electrotechnical Committee
標(biāo)準(zhǔn)頁數(shù):53
標(biāo)準(zhǔn)簡介

Applicable to a.c. circuit-breakers designed for indoor or outdoor installation, for operation at frequencies of 50 Hz and 60 Hz on systems having voltages above 1000 V and applied for inductive current switching with or without additional short-circuit current breaking duties. The standard is applicable to circuit-breakers in accordance with IEC 62271-100 that are used to switch high-voltage motor currents and shunt reactor currents and also to high-voltage contactors used to switch high-voltage motor currents. Switching unloaded transformers, i.e. breaking transformer magnetizing current, is not considered in this standard. The reasons for this are as follows: a) due to the non-linearity of the transformer core, it is not possible to correctly model the switching of transformer magnetizing current using linear components in a test laboratory. Tests conducted using an available transformer, such as a test transformer, will only be valid for the transformer tested and cannot be representative for other transformers; b) as detailed in the guide for application of IEC 62271-100 and IEC 60694, the characteristics of this duty are usually less severe than any other inductive current switching duty. It should be noted that such a duty may produce severe overvoltages within the transformer winding(s) depending on the circuit-breaker re ignition behaviour and transformer winding resonance frequencies. Short-line faults, out-of-phase current making and breaking and capacitive current switching are not applicable to circuit-breakers applied to switch shunt reactors or motors. These duties are therefore not included in this standard.

本標(biāo)準(zhǔn)替代的舊標(biāo)準(zhǔn)

IEC/TS 61233 Ed. 1.0

替代本標(biāo)準(zhǔn)的新標(biāo)準(zhǔn)

IEC 62271-110 Ed. 2.0

等同采用的國際標(biāo)準(zhǔn)

CEI EN 62271-110 Ed. 1 (2006) - Identical

SN EN 62271-110:2005 - Identical

BS EN 62271-110:2005 - Identical

DIN EN 62271-110 (2006-07) - Identical

VDE 0671-110:2006 - Identical

NF EN 62271-110:2006 - Identical

I.S. EN 62271-110:2005 - Identical

UNE EN 62271-110:2006 - Identical

SS EN 62271-110 Ed. 1 (2005) - Identical

PN EN 62271-110:2007 - Identical

NEN EN IEC 62271-110:2005 - Identical

AS 62271.110-2006 (R2016) - Identical

OVE/ONORM EN 62271-110:2006 - Identical