国产精品久久久在线观看_亚洲免费观看视频网站_国产盗摄视频一区二区三区_久久久国产一级 - 日本在线观看一区

歡迎來到寰標網! 客服QQ:772084082 加入會員
當前位置: 首頁 > 標準詳情頁

IEC 60909-3 Ed. 3.0現行

Short-circuit currents in three-phase AC systems Part 3: Currents during two separate simultaneous line-to-earth short circuits and partial short-circuit currents flowing through earth

出版:International Electrotechnical Committee

獲取原文 如何獲取原文?問客服 獲取原文,即可享受本標準狀態變更提醒服務!

專家解讀視頻

基本信息
標準編號: IEC 60909-3 Ed. 3.0
發布時間:2009/3/9 0:00:00
標準類別:Standard
出版單位:International Electrotechnical Committee
標準頁數:117
標準簡介

IEC 60909-3:2009 is available as IEC 60909-3:2009 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition. IEC 60909-3:2009 specifies procedures for calculation of the prospective short-circuit currents with an unbalanced short circuit in high-voltage three-phase a.c. systems operating at nominal frequency 50 Hz or 60 Hz, i. e.: - currents during two separate simultaneous line-to-earth short circuits in isolated neutral or resonant earthed neutral systems; - partial short-circuit currents flowing through earth in case of single line-to-earth short circuit in solidly earthed or low-impedance earthed neutral systems. The currents calculated by these procedures are used when determining induced voltages or touch or step voltages and rise of earth potential at a station (power station or substation) and the towers of overhead lines. Procedures are given for the calculation of reduction factors of overhead lines with one or two earth wires. This edition constitutes a technical revision. The main changes with respect to the previous edition are: - New procedures are introduced for the calculation of reduction factors of the sheaths or shields and in addition the current distribution through earth and the sheaths or shields of three-core cables or of three single-core cables with metallic non-magnetic sheaths or shields earthed at both ends; - The information for the calculation of the reduction factor of overhead lines with earth wires are corrected and given in the new Clause 7; - A new Clause 8 is introduced for the calculation of current distribution and reduction factor of three-core cables with metallic sheath or shield earthed at both ends; - The new Annexes C and D provide examples for the calculation of reduction factors and current distribution in case of cables with metallic sheath and shield earthed at both ends. The contents of the corrigendum of September 2013 have been included in this copy. This publication is to be read in conjunction with IE C 60909-0:2001

本標準替代的舊標準

IEC 60909-3 Ed. 2.0

等同采用的國際標準

BS EN 60909-3:2010 - Identical