Standard Test Method for Softening Point of Glass
出版:American Society for Testing and Materials

專家解讀視頻
1.1?This test method covers the determination of the softening point of a glass by determining the temperature at which a round fiber of the glass, nominally 0.65 mm in diameter and 235 mm long with specified tolerances, elongates under its own weight at a rate of 1 mm/min when the upper 100 mm of its length is heated in a specified furnace at the rate of 5 ± 1?°C/min.