国产精品久久久在线观看_亚洲免费观看视频网站_国产盗摄视频一区二区三区_久久久国产一级 - 日本在线观看一区

歡迎來到寰標(biāo)網(wǎng)! 客服QQ:772084082 加入會員
當(dāng)前位置: 首頁 > 標(biāo)準(zhǔn)詳情頁

JIS T 1201-1:2000被替代

Audiometers Part 1: Pure-tone audiometers

出版:Japanese Standards Association

獲取原文 如何獲取原文?問客服 獲取原文,即可享受本標(biāo)準(zhǔn)狀態(tài)變更提醒服務(wù)!

專家解讀視頻

基本信息
標(biāo)準(zhǔn)編號: JIS T 1201-1:2000
發(fā)布時間:2000/8/1 0:00:00
標(biāo)準(zhǔn)類別:Standard
出版單位:Japanese Standards Association
標(biāo)準(zhǔn)頁數(shù):51
標(biāo)準(zhǔn)簡介

This part of JIS T 1201 specifies general requirements for audiometers and particular requirements for pure-tone audiometers designed for use in determining hearing threshold levels in comparison with the standard reference threshold level by means of psycho-acoustic test methods. The purpose of this part is to ensure: a) that tests of hearing, particularly threshold, on a given human ear performed with different audiometers which comply with this part using methods described in ISO 8253-1 and ISO 6189 shall give substantially the same results; b) that the results obtained represent a valid comparison between the hearing of the ear tested and the reference threshold of hearing. Audiometers can be classified in the following ways: according to the type of test signal they generate, according to the mode of operation or according to the complexity of the range of auditory functions they test (i.e. diagnostic, screening, etc.). However, in order to rationalize the classification of audiometers, five types are defined. Audiometers with which it is possible to make a diagnostic assessment (i.e. having as a minimum both air and bone conduction facilities) are classified as types 1, 2 and 3. Instruments with air conduction facilities only are classified as types 4 and 5. This part covers the general requirements for audiometers as a whole as well as their functional units: signal sources, signal level controls and transducers (earphones and bone vibrators). In addition, since the units specified cover the majority of audiometric applications, instruments which may not necessarily be conventional pure-tone audiometers and not specified in this part (such as an auditory stimulator for evoked potential recording), but which contain circuitry used for measurement of auditory sensitivity or presentation of supraliminal signals should, where possible, conform to the appropriate clauses of this part.

本標(biāo)準(zhǔn)替代的舊標(biāo)準(zhǔn)

JIS T 1201:1982

替代本標(biāo)準(zhǔn)的新標(biāo)準(zhǔn)

JIS T 1201-1:2011

等同采用的國際標(biāo)準(zhǔn)

IEC 60645-1 Ed. 2.0 - Identical