Hydraulic Fluid Power - Four-screw, Split-flange Connections For Use At Pressures Of 2,5 Mpa To 40 Mpa (25 Bar To 400 Bar) - Type 1 Metric Series And Type 2 Inch Series
出版:Nederlands Normalisatie Instituut

專家解讀視頻
Provides complete general and dimensional specifications. For flange connections, a minimum design factor of 2,5 is valid with screws of property class 8.8, not including weld joints, for which special instructions exist. Also specifies appropriate references to the O-ring seals and their assembly components (ISO 3601-1, ISO 48 and ISO 3601-3) as well as recommended port dimensions and port design considerations.
ISO 6162:1994 - Identical