国产精品久久久在线观看_亚洲免费观看视频网站_国产盗摄视频一区二区三区_久久久国产一级 - 日本在线观看一区

歡迎來到寰標(biāo)網(wǎng)! 客服QQ:772084082 加入會員
當(dāng)前位置: 首頁 > 標(biāo)準(zhǔn)詳情頁

IEC/IEEE 63195-2:2022現(xiàn)行

Assessment of power density of human exposure to radio frequency fields from wireless devices in close proximity to the head and body (frequency range of 6 GHz to 300 GHz) - Part 2: Computational procedure

出版:

獲取原文 如何獲取原文?問客服 獲取原文,即可享受本標(biāo)準(zhǔn)狀態(tài)變更提醒服務(wù)!

專家解讀視頻

基本信息
標(biāo)準(zhǔn)編號: IEC/IEEE 63195-2:2022
標(biāo)準(zhǔn)類別:Standard
出版單位:
標(biāo)準(zhǔn)頁數(shù):0
標(biāo)準(zhǔn)簡介

IEC/IEEE 63195-2:2022 specifies computational procedures for conservative and reproducible computations of power density (PD) incident to a human head or body due to radio-frequency (RF) electromagnetic field (EMF) transmitting devices. The computational procedures described are finite-difference time-domain (FDTD) and finite element methods (FEM), which are computational techniques that can be used to determine electromagnetic quantities by solving Maxwell’s equations within a specified computational uncertainty. The procedures specified here apply to exposure assessments for a significant majority of the population during the use of hand-held and body-worn RF transmitting devices. The methods apply to devices that can feature single or multiple transmitters or antennas, and that can be operated with their radiating part or parts at distances up to 200 mm from a human head or body.This document can be employed to determine conformity with any applicable maximum PD requirements of different types of RF transmitting devices used in close proximity to the head and body, including those combined with other RF transmitting or non-transmitting devices or accessories (e.g. belt-clip), or embedded in garments. The overall applicable frequency range of these protocols and procedures is from 6 GHz to 300 GHz.The RF transmitting device categories covered in this document include but are not limited to mobile telephones, radio transmitters in personal computers, desktop and laptop devices, and multi-band and multi-antenna devices.The procedures of this document do not apply to PD assessment of electromagnetic fields emitted or altered by devices or objects intended to be implanted in the body.NOTE?For the assessment of the combined exposure from simultaneous transmitters at frequencies below 6 GHz, the relevant standards for SAR computation are IEC/IEEE 62704-1:2017 and IEC/IEEE 62704-4:2020.This publication is published as an IEC/IEEE Dual Logo standard.

等同采用的國際標(biāo)準(zhǔn)

DS/EN IEC/IEEE 63195-2:2023 - Identical

PN-EN IEC/IEEE 63195-2:2023-11 - Identical

UNE-EN IEC/IEEE 63195-2:2023 - Identical