国产精品久久久在线观看_亚洲免费观看视频网站_国产盗摄视频一区二区三区_久久久国产一级 - 日本在线观看一区

歡迎來到寰標(biāo)網(wǎng)! 客服QQ:772084082 加入會員
當(dāng)前位置: 首頁 > 標(biāo)準(zhǔn)詳情頁

IEC 60731 Ed. 3.0現(xiàn)行

Medical electrical equipment - Dosimeters with ionization chambers as used in radiotherapy

出版:International Electrotechnical Committee

獲取原文 如何獲取原文?問客服 獲取原文,即可享受本標(biāo)準(zhǔn)狀態(tài)變更提醒服務(wù)!

專家解讀視頻

基本信息
標(biāo)準(zhǔn)編號: IEC 60731 Ed. 3.0
發(fā)布時(shí)間:2011/2/25 0:00:00
標(biāo)準(zhǔn)類別:Standard
出版單位:International Electrotechnical Committee
標(biāo)準(zhǔn)頁數(shù):203
標(biāo)準(zhǔn)簡介

IEC 60731:2011 specifies the performance requirements of radiotherapy dosimeters, intended for the measurement of absorbed dose to water or air kerma (and their rates and spatial distributions) in photon, electron, proton or heavy ion radiation fields as used in radiotherapy. The dose monitoring systems incorporated in radiotherapy treatment machines are not covered by this standard, neither are the re-entrant ionization chambers used for brachytherapy source calibration and constancy check devices. IEC 60731:2011 is applicable to the following types of dosimeter: a) field-class dosimeters normally used for 1) in vivo skin surface or intracavitary measurements of dose on patients. 2) in vivo skin surface or intracavitary measurements of dose on patients. b) reference-class dosimeters normally used for the calibration of field-class dosimeters; c) scanning-class dosimeters normally used for relative dose distribution measurements with a scanning system such as an automatic water phantom. The object of this standard is: - to establish requirements for a satisfactory level of performance for radiotherapy dosimeters; - to standardize methods for the determination of compliance with this level of performance. Three levels of performance are specified: - a lower level of performance applying to field-class dosimeters; - a higher level of performance applying to reference-class dosimeters; - a specific level of performance applying to scanning-class dosimeters. This third edition cancels and replaces the second edition published in 1997 and its Amendment 1 (2002) and constitutes a technical revision. The technical modifications versus the second edition of this standard concerns performance requirements of radiotherapy dosimeters intended for the measurement of absorbed dose to water or air kerma in heavy ion radiation fields and scanning-class dosimeters normally used for relative dose distribution measurements with a scanning system such as an automatic water phantom.

本標(biāo)準(zhǔn)替代的舊標(biāo)準(zhǔn)

IEC 60731 Ed. 2.0

替代本標(biāo)準(zhǔn)的新標(biāo)準(zhǔn)

IEC 60731 Ed. 3.1

等同采用的國際標(biāo)準(zhǔn)

BS EN 60731:2012 - Identical

本標(biāo)準(zhǔn)修訂后的版本

IEC 60731 Amd.1 Ed. 3.0 -