BS 1042-1.3:1991被替代

Measurement Of Fluid Flow In Closed Circuits - Pressure Differential Devices - Method Of Measurement Of Gas Flow By Means Of Critical Flow Venturi Nozzles

出版:British Standards Institution

獲取原文 如何獲取原文?問客服 獲取原文,即可享受本標準狀態變更提醒服務!

專家解讀視頻

基本信息
標準編號: BS 1042-1.3:1991
發布時間:1991/10/31 0:00:00
標準類別:Standard
出版單位:British Standards Institution
標準頁數:20
標準簡介

Describes the geometry and method of use of critical flow Venturi nozzles used to determine the mass flow-rate of a gas flowing through a system. It gives the information necessary for calculating the flow-rate and its associated uncertainty. Applies to Venture nozzles in which the gas flow accelerates to the critical velocity at the throat. Applicable only where there is steady flow of single-phase gases. It deals with Venturi nozzles for which direct calibration experiments have been made in sufficient number and quantity to enable inherent systems of application to be based on their results. BS AMD 8878 RENUMBERS THIS STANDARD

標準備注

? British Standards Institution 2013

Renumbered and superseded by BS EN ISO 9300
Supersedes 89/20802 DC
(09/2005)

等同采用的國際標準

ISO 9300:2005 - Identical